Critical (9.8)

iOS Buffer Overflow (CVE-2026-22891)

CVE-2026-22891

A heap-based buffer overflow vulnerability exists in the Intan CLP parsing functionality of The Biosig Project libbiosig 3.9.2 and Master Branch (db9a9a63). A specially crafted Intan CLP file can lead...

Overview

A critical security vulnerability has been identified in The Biosig Project’s libbiosig, a software library used for reading and writing biomedical signal data formats. The flaw resides in how the library processes files in the Intan CLP format.

In simple terms, the software does not properly check the size of data being written into a section of memory (the heap). By creating a specially crafted, malicious Intan CLP file, an attacker can overflow this memory buffer. This corruption can be exploited to run arbitrary code on the affected system.

Vulnerability Details

  • CVE Identifier: CVE-2026-22891
  • Affected Versions: libbiosig version 3.9.2 and the Master Branch (commit db9a9a63).
  • Vulnerability Type: Heap-based Buffer Overflow
  • CVSS Score: 9.8 (Critical)

The vulnerability is triggered when libbiosig parses a maliciously crafted .clp file. Successful exploitation does not require user interaction beyond opening the file in a vulnerable application that uses the library.

Potential Impact

The impact of this vulnerability is severe. If successfully exploited, an attacker could:

  • Execute Arbitrary Code: Gain the ability to run commands or programs on the victim’s system with the same privileges as the application using libbiosig.
  • Compromise System Integrity: Install malware, create backdoors, or steal sensitive data.
  • Disrupt Operations: Cause the vulnerable application to crash, leading to a denial of service.

Any software, research tool, or medical data analysis platform that incorporates the vulnerable version of libbiosig to process Intan CLP files is at risk.

Remediation and Mitigation

Immediate action is required to protect systems.

Primary Remediation:

  1. Upgrade the Library: The most effective solution is to update libbiosig to a patched version once the maintainers release one. Monitor the official Biosig Project website for security updates and patches addressing CVE-2026-22891.
  2. Update Dependent Applications: If you use software that bundles libbiosig, contact the vendor for a patched application update.

Immediate Mitigations (if patching is not yet possible):

  • Restrict File Processing: Avoid processing Intan CLP (.clp) files from untrusted or unknown sources.
  • Implement Input Validation: If you develop software using libbiosig, implement strict file-type and source validation before parsing.
  • Use Principle of Least Privilege: Run applications that use libbiosig with the minimum necessary system privileges to reduce the potential impact of successful exploitation.
  • Network and Host Segmentation: Isolate systems that must process these files from critical network segments.

System administrators and developers should assess their software inventory for the use of libbiosig and apply patches as soon as they become available.

Share:

Never miss a critical vulnerability

Get real-time security alerts delivered to your preferred platform.

Related Advisories

Never Miss a Critical Alert

CVE advisories, breach reports, and threat intel — delivered daily to your inbox.